Solar Calculator Canada

Solar Power Calculator for Burnaby, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Burnaby
  • GPS Coordinates: 49.242778, -122.972778
  • Elevation: 48 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Burnaby: 37o
  • Average yearly irradiance: 1353.26 kWh/m2
  • Average yearly power output: 110350 kWh
Sun Path Burnaby

Average yearly irradiance delivered by the Sun in Burnaby is 1353.26/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 110350 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.28 39.71
February 2.52 70.45
March 3.12 96.57
April 4.53 135.88
May 5.36 166.13
June 5.29 158.67
July 6.41 198.75
August 5.85 181.31
September 4.59 137.74
October 2.72 84.4
November 1.6 48.04
December 1.15 35.6
Total yearly 1353.26

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 108.35 3358.8
February 214.34 6001.51
March 262.74 8144.9
April 377.71 11331.3
May 437.47 13561.7
June 425.42 12762.7
July 507.39 15728.9
August 463.05 14354.4
September 368.7 11061.1
October 224.32 6953.86
November 135.17 4055.17
December 97.92 3035.6
Total yearly 110350

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Burnaby solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 79.99 2479.64
February 170.5 4774.11
March 235.74 7307.82
April 365.73 10971.8
May 447.48 13871.9
June 448.87 13466
July 527.17 16342.2
August 454.43 14087.5
September 332.62 9978.73
October 186.5 5781.47
November 100.39 3011.82
December 68.93 2136.89
Total yearly 104210

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.79 2721.36
February 182.98 5123.41
March 244.44 7577.7
April 371.63 11149
May 448.46 13902.2
June 446.29 13388.7
July 526.27 16314.2
August 460.19 14266
September 344.33 10329.9
October 197.42 6120.11
November 110 3299.88
December 76.94 2385.26
Total yearly 106578

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 94.86 2940.64
February 194.1 5434.88
March 251.71 7803.11
April 375.6 11268
May 447.15 13861.8
June 442.18 13265.4
July 523.4 16225.3
August 463.33 14363.2
September 353.9 10617.1
October 207.01 6417.16
November 118.69 3560.66
December 84.24 2611.51
Total yearly 108369

Burnaby Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.18 3136.72
February 203.85 5707.76
March 257.52 7983.26
April 377.61 11328.2
May 443.61 13751.8
June 435.62 13068.7
July 517.41 16039.6
August 463.92 14381.7
September 361.34 10840.2
October 215.22 6671.83
November 126.45 3793.38
December 90.81 2815.07
Total yearly 109518

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.85% angle of incidence loss and -6.74% temperature and irradiance loss. This totals to about -18.46%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville